Method of installation: 150mm centres bathroom areas 200mm centres living areas
Control Panel: 5@100m, 10@200, 15@300 Circuit Manifold
Thermostatic control: 1 Slab thermostat
Included is the following:
- In-floor Pipework supply and installation
- Control Panel including pump, Manifolds, air vent, pressure vent, pressure gauge in in-wall cabinet supply and installation
- Gas boiler supply and installation, including plumbing and Gasfitting certifications
- 1 x air thermostat controller supply only
- Commissioning of system
- Customer education visit
- All electrical instructions, colour coded heating drawings, producer statements and warranties
** Conditions: It is the owners / builders responsibility to supply power to control panel, boiler an room thermostat. Electrical services not included but can be provided by Euro Plumbing.
Please note: All packages above are based on GAS LPG / NG and can be upgraded to a HEATPUMP option where gas is less desirable. Combination systems such as solar or heatpumps + gas are also available and can offset cost as preheaters.